Page 4 - 태화트랜스
P. 4

Supreme Accuracy Current Transformers






































                Application                                     General Features

                •   0.1 / 0.2 Class 1A, 5A rating accuracy meters  in   •   Compliant to IEC61869-2, IEC62053-22 & ANSI
                   HVCT & MVCT for power & sub-stations and       C12.20
                   industrial & commercial meters
                                                                •   Paramount linearity within 0.1% through whole
                •  Data logger in digital fault recorders         range
                •  Energy measurement of HEMS,BEMS,FEMS         •  Nearly zero tolerance on temperature change
                •  Accuracy multi-harmonics measurements        •  Hi-potential : 4kV per min.
                •  Arc plasma current monitoring up to 100Khz   •  Optional to measure the multi-harmonics

                •  EV charging cable & station                  •  RoHS & REACH compliant

                Circuit Diagram

                Imax.rms≒2πfBsAeN²sec/ (Rcu+RB)
                Idcmax≒nBs.le/µ
                Phase Error Ф(|)=arctan(Rcu+RB)/2πfL
                Amplitude Error F(I) ≒ -sino•(Rcu + RB)/2πfµ
                Eo = K. lo . RL / n